NAS Codex › QNAP › QNAP "[Disk S.M.A.R.T.] Disk x still has warning/error condition": what to do

QNAP "[Disk S.M.A.R.T.] Disk x still has warning/error condition": what to do

The QNAP log keeps repeating [Disk S.M.A.R.T.] Host: Disk x still has warning/error condition. Please check the summary page. QNAP lists this among the alerts that mean a disk should be replaced if they keep coming back. Below is what QNAP says the warning means, and QNAP's own replacement procedure in a safe order.

Written against: QTS and QuTS hero (QNAP FAQ last modified 2023-07-28; QTS 5.1.x documentation). Last Updated: November 2026. Vendor menus and wording change between versions; if yours differ, follow the vendor page linked under Sources.

Before anything else: if the data on this NAS is not backed up somewhere else, copy it off first. Do not continue with any step on this page until you have.

Fast Answer

The message repeats because a disk's S.M.A.R.T. data has crossed a threshold and stayed there. Open Storage & Snapshots > Storage > Disks/VJBOD, select the disk and check its health. QNAP's definitions: Warning means S.M.A.R.T. errors were detected, so run a full S.M.A.R.T. test and a disk scan; Error means I/O errors were detected and the disk must be replaced immediately. Back up first, then replace the disk only if the number of faulty disks is within your RAID group's fault tolerance.

The message

[Disk S.M.A.R.T.] Host: Disk x still has warning/error condition. Please check the summary page

QNAP's disk-warning FAQ names four alerts that mean a disk should be replaced if they repeat. This is one of them. The others are the pool status Warning (Degraded), the log entry Disk drive X failed or is unplugged, and the medium error message. "Disk x" is the bay number.

Step 1: Look at the summary page the message refers to

  1. Go to Storage & Snapshots > Storage > Disks/VJBOD > Disks.
  2. Select the disk and click Health. Click View Details for all the health information.
  3. The Summary tab shows an overview of the S.M.A.R.T. information and the results of the most recent disk scan and S.M.A.R.T. test.
  4. Under S.M.A.R.T. information, QNAP explains that an attribute's status changes to Warning when it reaches the manufacturer's or QTS's threshold. That attribute is the reason for the message.

Step 2: Run the tests QNAP asks for

For a disk in Warning, QNAP's disk status table says: "Run a full S.M.A.R.T. test and a disk scan."

Step 3: Back up before you touch the disk

QNAP's FAQ says your next steps depend on the number of faulty disks and your RAID group:

Check how many disks in the same RAID group show Warning or Error before you go further. QNAP's medium-error FAQ suggests clicking RAID Group to see which RAID group a disk belongs to and its RAID type.

Step 4: QNAP's replacement procedure

Confirm the bay number against the Disks/VJBOD screen before you pull anything. Pulling the wrong disk from a pool that is already short of redundancy can take the whole RAID group offline.

  1. In Storage & Snapshots > Storage > Disks/VJBOD, check the disk slot status.
  2. Without shutting off the NAS, remove the faulty disk and wait for the alert beep. (QNAP's inactive-disk FAQ adds: do not remove or insert disks while the NAS is running unless your model supports hot swapping. Check your model's user guide.)
  3. Insert the new disk.
  4. On Disks/VJBOD, confirm the new disk is detected. If it is detected but the rebuild does not start, set it as a spare disk (see rebuild not starting). If it is not detected, remove it, leave the slot empty, reboot, and start again from step 1.
  5. Go to Storage & Snapshots > Storage > Storage/Snapshots to watch the rebuild.

QNAP lists three things to watch for during and after the rebuild: the pool going read-only (see degraded read-only); a rebuild that keeps stopping, which may mean another disk is faulty, so back up immediately; and a later failure in the same slot, in which case test the disk on a PC with a diagnostic tool.

When to stop and get help

Stop if more disks in the RAID group are faulty than it can tolerate, if the pool shows Warning (Read-Only) or Not Active, or if the rebuild keeps stopping. QNAP's advice in each case is to back up first; if File Station can no longer reach the data, contact QNAP support or a recovery professional rather than replacing more disks.

Questions

What does "Disk x still has warning/error condition" mean on QNAP?

A disk's S.M.A.R.T. information has reached a warning threshold and has not cleared. QNAP lists the message among the alerts that mean a disk should be replaced if it keeps repeating.

Should I replace a QNAP disk in Warning status?

QNAP's disk status table says Warning means S.M.A.R.T. errors were detected and you should run a full S.M.A.R.T. test and a disk scan. Error means I/O errors were detected and the disk must be replaced immediately.

Can I replace the disk while the NAS is on?

QNAP's replacement steps remove the disk without shutting off the NAS, but its inactive-disk FAQ warns not to do so unless your model supports hot swapping. Check your model's user guide, and back up first.

Sources

Every fact on this page comes from the vendor documents below, opened on 2026-11-13.