A UPS only protects a QNAP NAS if the NAS knows about it and is set to shut down in time. QNAP's FAQs cover choosing a compatible UPS, connecting it by USB or SNMP, the settings in QTS and QuTS hero, how to test it, how the NAS reacts to each UPS state, and how one NAS can pass shutdown signals to others. This page puts them together.

Written against: QTS and QuTS hero, all NAS series (QNAP FAQs last modified 2022-06-24, 2024-08-13 and 2025-06-27). Last Updated: November 2026. Vendor menus and wording change between versions; if yours differ, follow the vendor page linked under Sources.

Before anything else: if the data on this NAS is not backed up somewhere else, copy it off first. Do not continue with any step on this page until you have.

Fast Answer

Check the UPS is on QNAP's compatibility list for your NAS model. Plug its USB cable into the NAS (QNAP says the NAS detects it automatically), or set it up as a network UPS over SNMP. Then go to Control Panel > System > External Device > UPS, tick Enable UPS support, and set the NAS to shut down after a few minutes of power loss; QNAP recommends 3 to 5 minutes. Finally, unplug the UPS from the wall and check that the NAS sees it on battery and shuts down after the delay.

Why it matters

QNAP says power outages or voltage fluctuations can cause data corruption or system failure, and that a compatible UPS lets you prevent data loss and shut the system down safely.

Step 1: choose a compatible UPS

QNAP says to check its Compatibility List to confirm the UPS is supported by your NAS model. Its examples of compatible Smart UPS models include the APC SMT1000IC (Smart-UPS with USB), the CyberPower PR1500ELCD (rackmount, USB or SNMP), the Nitram ELITE PRO 1000ELCDRT2U (rackmount, USB), the Eaton 5PX1500iRT (Smart Line-Interactive) and the APC SMX1500RMI2U (rackmount, SNMP or USB).

Step 2: connect the UPS

Step 3: set it up in QTS or QuTS hero

  1. Go to Control Panel > System > External Device > UPS.
  2. Tick Enable UPS support.
  3. Set the NAS to shut down after a number of minutes of power loss. QNAP recommends 3 to 5 minutes.
  4. Turn on notifications so you get alerts.
  5. For an SNMP UPS, select Network UPS, enter the UPS's IP address and SNMP community string (QNAP says usually public), and test the connection.

Step 4: test it

QNAP says to unplug the UPS from its power source and check three things: the NAS detects that the UPS is on battery, the NAS starts a shutdown after the delay you set, and you receive system logs or notifications about the power loss and shutdown.

How the NAS reacts to the UPS

QNAP's FAQ on UPS events lists what QTS and QuTS hero do with each UPS state:

QNAP adds that the NAS normally checks the UPS every 15 seconds. When it sees OnBattery (outside a battery test), it starts the Auto-protection or Shutdown countdown you configured; if the UPS is in low-battery mode, that countdown is automatically set to 30 seconds. In Auto-protection or Shutdown mode it checks every 5 seconds until it powers off, and it returns to normal when the UPS goes back to OnLine.

Protecting more than one NAS

The setup FAQ lists an option to Enable network UPS master, which lets other NAS systems follow the shutdown instructions. A separate QNAP FAQ says that when a NAS is connected to the UPS by USB, you can add up to 20 UPS slave connections: in Control Panel > External Devices > UPS, select Enable network UPS master and click Add to enter each slave's IP address.

When to stop and get help

Test before you rely on it: QNAP's own step is to unplug the UPS and watch the NAS shut down after the delay. If the NAS has already been cut off by a power failure in the middle of a firmware update, see QNAP firmware update failed or stuck.

Questions

How do I make my QNAP NAS shut down when the power goes out?

QNAP says to connect a compatible UPS by USB or SNMP, go to Control Panel > System > External Device > UPS, tick Enable UPS support, and set the NAS to shut down after 3 to 5 minutes of power loss.

How often does a QNAP NAS check the UPS?

QNAP says every 15 seconds normally, and every 5 seconds once it is in Auto-protection or Shutdown mode. If the UPS reports low battery, the countdown is set to 30 seconds.

Can one UPS protect several QNAP NAS?